Heritage
Case Study

Suburb:

East Victoria Park Western Australia

Building:

Privately owned Brick & Iron Roof East Victoria Park Police Station

Problem:

Extensive concrete cancer to main fabric of the building including extensive concrete cancer to structural beams & columns

Service carried out:

  • Existing corroded lintels exposed by cutting and breaking out surrounding concrete and brickwork.
  • Lintels replaced with new hot dipped galvinised steel lintels.
  • New lintels encased in modified acrylic mortar.
  • Sand finish render applied to match existing.

Click image for a detailed image